{"id":13120,"date":"2026-09-08T19:07:05","date_gmt":"2026-09-08T16:07:05","guid":{"rendered":"https:\/\/militra.com\/product\/cu-medical-ipad-cu-spr-pusiau-automatinis-isorinis-defibriliatorius-ip66\/"},"modified":"2026-10-14T19:47:37","modified_gmt":"2026-10-14T16:47:37","slug":"cu-medical-ipad-cu-spr-pusiau-automatinis-isorinis-defibriliatorius-ip66","status":"publish","type":"product","link":"https:\/\/militra.com\/en\/product\/cu-medical-ipad-cu-spr-pusiau-automatinis-isorinis-defibriliatorius-ip66\/","title":{"rendered":"Cu Medical iPAD CU-SPR \u2013 semi-automatic external defibrillator, IP66"},"content":{"rendered":"<p class=\"m-ats\"><strong>iPAD CU-SPR \u2013 an improved version of the iPAD CU-SP1, which has been on the market for over a decade. The main difference is the IP66 protection class. This is the highest level of dust and water protection among currently available automated external defibrillators.<\/strong><\/p>\n<h2>Purpose<\/h2>\n<p>The model is designed for where the equipment faces more: outdoors, in a production workshop, on a construction site, at a port, in a warehouse. The device operates from 0 \u00b0C to +50 \u00b0C, withstands drops from 0.75 m, and the inserted battery lasts up to 5 years \u2013 so daily maintenance is minimal.<\/p>\n<p>The electrodes are suitable for both adults and children \u2013 the child mode is activated with one button, separate purchase of child electrodes is not required.<\/p>\n<h2>Features<\/h2>\n<p>iPAD CU-SPR is chosen by those who find a standard office defibrillator insufficient. IP66 means that the device is protected not only from dust but also from strong water jets \u2013 making it suitable for areas with moisture, dust, or temperature fluctuations.<\/p>\n<h3>Easy to use with no setup<\/h3>\n<p>The device guides step by step with voice commands and light indicators. It analyzes the rhythm itself and only delivers a shock when it is truly needed \u2013 by pressing the button.<\/p>\n<h3>Low maintenance<\/h3>\n<ul>\n<li>Self-check occurs when the device is turned on, during operation, daily, weekly, and monthly. The condition is visible from the indicator, nothing needs to be opened.<\/li>\n<li>Data is provided according to the manufacturer's technical specifications table (CU Medical, iPAD CU-SPR). Where it says 'no data', the manufacturer does not disclose the data \u2013 we do not speculate or copy it from other stores.<\/li>\n<\/ul>\n<h2>Technical data<\/h2>\n<table class=\"m-spec\">\n<tbody>\n<tr>\n<th>Device type<\/th>\n<td>semi-automatic external defibrillator (AED)<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>iPAD CU-SPR<\/td>\n<\/tr>\n<tr>\n<th>Defibrillation technology<\/th>\n<td>e-cube biphasic wave form (Biphasic Truncated Exponential)<\/td>\n<\/tr>\n<tr>\n<th>Energy level<\/th>\n<td>150 J or 200 J for adults (at 50 \u03a9), 50 J for children<\/td>\n<\/tr>\n<tr>\n<th>Shock delivery<\/th>\n<td>by pressing the button if the analysis shows that a shock is necessary<\/td>\n<\/tr>\n<tr>\n<th>Protection rating<\/th>\n<td>IP66 (IEC 60529:2013) \u2013 the highest among currently available AID<\/td>\n<\/tr>\n<tr>\n<th>Operating and standby temperature<\/th>\n<td>from 0 \u00b0C to +50 \u00b0C, humidity 5\u201395 % (without condensation)<\/td>\n<\/tr>\n<tr>\n<th>Storage and transport temperature<\/th>\n<td>from \u221220 \u00b0C to +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Drop resistance<\/th>\n<td>from 0.75 m on any edge, corner or surface<\/td>\n<\/tr>\n<tr>\n<th>Battery<\/th>\n<td>disposable LiMnO2, 12 V \/ 2.8 Ah<\/td>\n<\/tr>\n<tr>\n<th>Battery capacity<\/th>\n<td>at least 200 discharges of 150 J (about 3 hours of operation) or 150 discharges of 200 J (about 2 hours)<\/td>\n<\/tr>\n<tr>\n<th>Battery standby time<\/th>\n<td>at least 5 years from the date of manufacture<\/td>\n<\/tr>\n<tr>\n<th>Electrodes<\/th>\n<td>adults and children \u2013 at least 36 months; children's \u2013 at least 30 months from production; area 85 cm\u00b2, cord 120 cm<\/td>\n<\/tr>\n<tr>\n<th>Self-test<\/th>\n<td>when turned on, during operation, daily, weekly and monthly<\/td>\n<\/tr>\n<tr>\n<th>Memory<\/th>\n<td>5 separate resuscitation events, up to 3 hours each; transfer via IrDA or USB<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>2.4 kg (with battery and electrodes)<\/td>\n<\/tr>\n<tr>\n<th>Dimensions<\/th>\n<td>240 \u00d7 230 \u00d7 70 mm<\/td>\n<\/tr>\n<tr>\n<th>Manufacturer<\/th>\n<td>CU Medical Systems, Inc. (South Korea)<\/td>\n<\/tr>\n<tr>\n<th>Manufacturer\u2019s warranty<\/th>\n<td>no data \u2013 the manufacturer does not publicly disclose this information. If this is important for your decision, please write to us and we will clarify.<\/td>\n<\/tr>\n<tr>\n<th>Languages<\/th>\n<td>no data \u2013 the manufacturer does not publicly disclose this information. If this is important for your decision, please write to us and we will clarify.<\/td>\n<\/tr>\n<tr>\n<th>Product code<\/th>\n<td>DCUMEDICALSPR<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Frequently asked questions<\/h2>\n<h3>How much does delivery cost?<\/h3>\n<p>The delivery of this item is \u20ac5.99 by courier. You can pick it up in Vilnius, S. \u017dukausko g. 35 for free.<\/p>\n<h3>Is VAT included in the price?<\/h3>\n<p>Yes. All prices displayed in the store include 21% VAT.<\/p>\n<h3>Can I buy in a company\u2019s name?<\/h3>\n<p>Yes. For larger quantities or corporate orders, we prepare a separate offer \u2013 fill out the form. <a href=\"\/en\/gauti-pasiulyma\/\">Get a quote<\/a> or write to info@militra.lt.<\/p>\n<p class=\"m-saltinis\"><em>Data is provided according to the manufacturer's technical specifications table (CU Medical, iPAD CU-SPR). Where it says 'no data', the manufacturer does not disclose the data \u2013 we do not speculate or copy it from other stores.<\/em><\/p>","protected":false},"excerpt":{"rendered":"<p><strong>iPAD CU-SPR<\/strong> \u2013 an improved version of the iPAD CU-SP1 that has been on the market for over a decade. The main difference is <strong>IP66 protection class<\/strong>. This is the highest level of protection against dust and water among currently available automated external defibrillators.<\/p>\n<p>The model is designed for situations where the equipment faces more: <strong>outdoors, in the production workshop, on construction sites, at the port, in the warehouse<\/strong>. The device operates from 0 \u00b0C to +50 \u00b0C, withstands drops from 0.75 m, and the inserted battery is on standby <strong>up to 5 years<\/strong> \u2013 so daily maintenance is minimal.<\/p>\n<p>The electrodes are suitable for both adults and children \u2013 the child mode is activated with one button, separate purchase of child electrodes is not required.<\/p>\n<p class=\"militra-pristatymas\"><strong>Delivery: 7\u201314 working days<\/strong><\/p>","protected":false},"featured_media":13108,"comment_status":"open","ping_status":"closed","template":"","meta":{"slim_seo":{"title":"Cu Medical iPAD CU-SPR \u2013 pusiau automatinis i\u0161orinis defibriliatorius, IP66 - Militra elektronin\u0117 parduotuv\u0117","description":"iPAD CU-SPR \u2013 patobulinta jau daugiau nei de\u0161imtmet\u012f rinkoje esan\u010dio iPAD CU-SP1 versija. Svarbiausias skirtumas \u2013 IP66 apsaugos klas\u0117 . Tai auk\u0161\u010diausias apsaug"},"_slim_seo_primary_term_product_brand":0,"_slim_seo_primary_term_product_cat":0,"_slim_seo_primary_term_product_tag":0},"product_brand":[],"product_cat":[17,319],"product_tag":[],"class_list":["post-13120","product","type-product","status-publish","has-post-thumbnail","product_cat-defibriliatoriai","product_cat-pusiau-automatiniai-defibriliatoriai","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/product\/13120","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/comments?post=13120"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/media\/13108"}],"wp:attachment":[{"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/media?parent=13120"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/product_brand?post=13120"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/product_cat?post=13120"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/militra.com\/en\/wp-json\/wp\/v2\/product_tag?post=13120"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}